2-stage caustic scrubber for the removal of phenol
Challenge
- Emission limit of 20 mg/Nm³ for phenol
- Phenol is an explosive gas
- High-temperature area (up to 45°C)
Result
- Scrubber made of SS304L and instruments provided with sun cover
- 2-stage scrubber has a removal efficiency of 99,85%
- Complete scrubber skid is suited for atex zone 2 (IIA T3)
Our services
Study & consultancy
Design & build